NAVIGATION: Motor > PS motor

PS motor

Determining the motor data

There are two methods of creating a motor data set for the rotary synchronous motor.


Vorgehensweise: Motor calculation

 

ATTENTION:
All existing motor parameters are overwritten.




Bild: Calculation of PS motor


Calculated values


ATTENTION:
All existing control parameters are overwritten.


Parameters

P. no. Parameter name Function
P 0490 MOT_IsLinMot Selection for rotary or linear system
P 0450 MOT_Type -> PSM Motor type (ASM, PSM)
P 0451 MOT_Name 1) Freely selectable motor name
P 0455 MOT_FNom 2) Rated frequency of the motor
P 0456 MOT_VNom 2) Rated voltage of the motor
P 0457 MOT_CNom 2) Rated current of the motor
P 0458 MOT_SNom 2 Rated speed
P 0459 MOT_PNom 1) Rated power
P 0460 MOT_TNom 2) Nominal torque
P 0461 MOT_J 2) Mass inertia of the motor
P 0463 MOT_PolePairs 2) Number of pole pairs
P 0470 MOT_Rstat 2) Stator resistance: The phase resistance is taken into account in the calculation.
P 0471 MOT_Lsig 2) Stator inductance: The stator inductance is taken into account in the calculation.
P1530 SCD_SetMotor control Start of calculation
1) The parameters are only of informative nature, but should be set for a complete motor data set.

2) The parameters are used for calculation of controller settings, and have a direct effect on the response of the servocontroller.

Tabelle: Parameters to determine the motor data